Pocket Size Type Digital Multimeters UT120A

UT120 series is a portable, small 3 3/4 auto range digital multimeter. Its complete function, stable performance, high precision, low power consumption, novel structure, safe and reliable, easy to operate, wearable, durable, which is an ideal measuring instrument for users. It is suitable for measurement of smelting, communication, manufacturing, petroleum, national defense, electric power, chemical industry and other industries.

Product Comparison
Function Range ResolutionAccuracy±(a%+b)Input     protection Description 
DCV4V1mV±(0.8%+1)600V AC 
40V10mV
400V100mV
600V1V±(1%+3)

ACV
4V1mV± (1.2%+3)600V ACInput impedance ≥10MΩ
Frequency response:40∽400Hz
Display:Sine wave effective value (average value response)
40V10mV
400V100mV
600V1V±(1.5%+5)
Resistance (Ω)400Ω0.1Ω ±(1.2%+2)600V ACOpen circuit voltage about 0.45V
4kΩ± (1%+2)
40kΩ10Ω
400kΩ100Ω
4MΩ1kΩ±(1.2%+2)
40MΩ10kΩ±(1.5%+2)
Frequency (f)99.99Hz0.1Hz±(0.5%+3)600V ACIn the AC/Dc slot, press HZ/% button turn into Hz to measure

Accuracy :inputsine wave voltage 10Hz∽10kHz:≥1Vrms

10kHz∽100kHz:≥30Vrms

999.9Hz1Hz
9.999kHz0.01kHz
10MHz0.1kHZ
DUTY0.1%-99.9%0.10% 600V ACIn the AC/DC slot Press HZ/% button turn into DUTY to measure (Reading is for reference only    )
Diode  1mV0.5V∽0.8V600V ACOpen circuit voltage about 1.5V
Buzzer on-off
0.1ΩAbout ≤60Ω 600V AC60Ω either beep or not
SLEEP  About 30min About(5uA)
SELECTResistance/Capacitance/Diode /on-off change 
RELRelative Mode
HOLDData Hold 
Hz/%In the AC/DC/HZ/%slot(UT120A/B);PressHZ/% button turn into Hz/% to measure 
Low Battery    Indication   About <2.4V Display&ldquo; &rdquo;Symbol
1.Auto power off (When the instrument knob and the four buttons are not responding in 30 minutes, Instruments into sleep mode.
In the sleep mode, rotate button and the instrument will auto power on
2.In the sleep mode, press SELECT button to wake up instrument,auto power off function will be cancelled.
3.After testing Hz/% and returning to DCV and ACV, the slot range is DCV-400mV, ACV-4V.
AUTO disappears in the LCD. At this time testing higher voltage,the instrument must be powered off and reset DCV, ACV for automatic range. 